AC-DC Power Module
3 0 WaASC l SERIES t t U t r a m i niature Modular Switching Power Supplies
KEY FEATURES
Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Output Low Ripple and Noise High Efficiency CE, CB, cUL, TUV Approvals 2-Year Product Warranty
ASC
30
s Watts e r i e s
ELECTRICAL SPECIFICATIONS
Model No. ( Single Output ) ASC-3.3S
20W
47-440 Hz
520 mA max. (115 VAC) / 320 mA max. (230 VAC)
10 A max. (115 VAC) /20 A max. (230 VAC)
0.75 mA max.
1.5 A slow blow type
3.3V
2%
6000
1%
1%
5%
4%
2%
2%
2%
470-23,000F depending on model
<0.2% Vout +40mV max (Vp-p)
<0.5% Vout +50mV max (Vp-p)
70%
15 ms min.
100 kHz
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000 V
-25C...+70C (with derating)
-40C...+85C
0.02%/C
95% RH
>200,000 h @ 25C (MIL-HDBK-217F)
3.5 x 2.5 x 0.98 Inches
220 g
Free air convection
UL/cUL, CE, TUV, CB
EN 55022 class B
EN 55024
All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.
ASC-5S
30W
ASC-12S
30W
ASC-15S
30W
ASC-24S
30W
Max Output Wattage (W) Voltage
Frequency (Hz)
Input
90-264 VAC or 120-370 VDC
Current (Full load)
Inrush Current (<2ms)
Leakage Current
External Fuse (recommend)
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Load Regulation (5-00%) (typ.)
Minimum Load
Maximum Capacitive Load
Ripple
Noise
Efficiency
Hold-up Time
Switching Frequency
Over Power Protection
5V
6000
12V
2500
15V
2000
24V
1250
Output
75%
80%
80%
77%
Protection
Isolation
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Operating Temperature
Storage Temperature
Environment
Temperature Coefficient
Humidity
MTBF
Dimension (L x W x H)
Case Material
Weight
Cooling Method
Agency Approvals
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
( 89.0 x 63.5 x 25.0 mm ) Tolerance 0.5 mm
Physical
Plastic resin with Fiberglass (flammability to UL 94V-0)
Safety
EMC
http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319
-1-
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
VER : A_0
update : 94.03.21
AC-DC Power Module
3 0 Wa t t U l t r a m i niature Modular Switching Power Supplies
ASC SERIES
ELECTRICAL SPECIFICATIONS
Model No. ( Dual* * riple Output ) T ASC-5D
30W
47-440 Hz
520 mA max. (115 VAC) / 320 mA max. (230 VAC)
10 A max. (115 VAC) /20 A max. (230 VAC)
0.75 mA max.
1.5 A slow blow type
5V
2%
3000
1%
3%
2%
3%
1%
470-23,000F depending on model
<0.2% Vout +40mV max (Vp-p)
<0.5% Vout +50mV max (Vp-p)
73%
15 ms min.
100 kHz
Hiccup technique, auto-recovery
Zener diode clamp
Hiccup mode, indefinite (automatic recovery)
3000 V
-25C...+70C (with derating)
-40C...+85C
0.02%/C
95% RH
>200,000 h @ 25C (MIL-HDBK-217F)
3.5 x 2.5 x 0.98 Inches
220 g
Free air convection
UL/cUL, CE, TUV, CB
EN 55022 class B
EN 55024
ASC
30
Watts
series
ASC-12D
30W
ASC-15D
30W
ASC-5S12S
30W
ASC-5S12D
30W
ASC-5S15D
30W
Max Output Wattage (W) Voltage
Frequency (Hz)
Input
90-264 VAC or 120-370 VDC
Current (Full load)
Inrush Current (<2ms)
Leakage Current
External Fuse (recommend)
Voltage (V.DC.)
Voltage Accuracy
Current (mA) max
Line Regulation (LL-HL) (typ.)
Load Regulation (5-00%) (typ.)
Minimum Load
Maximum Capacitive Load
Ripple
Noise
Efficiency
Hold-up Time
Switching Frequency
Over Power Protection
12V
1250
15V
1000
5/12
3000/1250
1% / 5%
2% / 6%
20%
5/12
3000/630
5/15
3000/500
Output
20%
20%
78%
76%
77%
77%
76%
Protection
Isolation
Over Voltage Protection
Short Circuit Protection
Input-Output (V.AC)
Operating Temperature
Storage Temperature
Environment
Temperature Coefficient
Humidity
MTBF
Dimension (L x W x H)
Case Material
Weight
Cooling Method
Agency Approvals
EMI (Conducted & Radiated Emission)
EMS (Noise Immunity)
( 89.0 x 63.5 x 25.0 mm ) Tolerance 0.5 mm
Physical
Plastic resin with Fiberglass (flammability to UL 94V-0)
Safety
EMC
All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated.
Note
1. 2. The triple output required a minimum 20% loading on the output to maintain specified regulation. damage these devices; however they may not meet all listed specification. Load regulation for triple output: Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries. Auxiliary outputs (V2 and V3): 20% to 100% balanced on all outputs. Cross regulation for triple output: Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%. Auxiliary outputs (V2 and V3): Main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other auxiliary 25% to 100%. Operation under no-load condition will not
3.
http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319
-2-
WWW.ASTRODYNE.COM
300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181
VER : A_0
update : 94.03.21
3 0 Wa t t U l t r a m i niature Modular Switching Power Supplies
ASC SERIES
ASC
30
Dual
AC-DC Power Module
Watts
series
MECHANICAL DIMENSION
( Top View )
PIN#
SINGLE
5S/12S
Triple AC IN (N)
1
AC IN (N)
AC IN (N)
AC IN (N)
2
AC IN (L)
AC IN (L)
AC IN (L)
AC IN (L)
3
+DC OUT
+DC OUT
+12V
+DC OUT
4
NO PIN
NO PIN
+5V
+5V
5
-DC OUT
COMMON
+12 RTN
COMMON
6
NO PIN
NO PIN
+5 RTN
+5 RTN
7
NOCONNECT
-DC OUT
NO PIN
-DC OUT
BLOCK DIAGRAM
DERATING
WWW.ASTRODYNE.COM TEL: +886-2-26989508 FAX: +886-2-26981319
http://www.archcorp.com.tw
300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 -3-


▲Up To Search▲   

 
Price & Availability of ASC

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X