|
If you can't view the Datasheet, Please click here to try to view without PDF Reader . |
|
Datasheet File OCR Text: |
VER : A_0 update : 94.03.21 AC-DC Power Module 3 0 WaASC l SERIES t t U t r a m i niature Modular Switching Power Supplies KEY FEATURES Switching Power Module for PCB Mountable Fully Encapsulated Plastic Case Universal Input Range 90-264VAC, 47-440 Hz Regulated Output Low Ripple and Noise High Efficiency CE, CB, cUL, TUV Approvals 2-Year Product Warranty ASC 30 s Watts e r i e s ELECTRICAL SPECIFICATIONS Model No. ( Single Output ) ASC-3.3S 20W 47-440 Hz 520 mA max. (115 VAC) / 320 mA max. (230 VAC) 10 A max. (115 VAC) /20 A max. (230 VAC) 0.75 mA max. 1.5 A slow blow type 3.3V 2% 6000 1% 1% 5% 4% 2% 2% 2% 470-23,000F depending on model <0.2% Vout +40mV max (Vp-p) <0.5% Vout +50mV max (Vp-p) 70% 15 ms min. 100 kHz Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000 V -25C...+70C (with derating) -40C...+85C 0.02%/C 95% RH >200,000 h @ 25C (MIL-HDBK-217F) 3.5 x 2.5 x 0.98 Inches 220 g Free air convection UL/cUL, CE, TUV, CB EN 55022 class B EN 55024 All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. ASC-5S 30W ASC-12S 30W ASC-15S 30W ASC-24S 30W Max Output Wattage (W) Voltage Frequency (Hz) Input 90-264 VAC or 120-370 VDC Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) max Line Regulation (LL-HL) (typ.) Load Regulation (5-00%) (typ.) Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection 5V 6000 12V 2500 15V 2000 24V 1250 Output 75% 80% 80% 77% Protection Isolation Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension (L x W x H) Case Material Weight Cooling Method Agency Approvals EMI (Conducted & Radiated Emission) EMS (Noise Immunity) ( 89.0 x 63.5 x 25.0 mm ) Tolerance 0.5 mm Physical Plastic resin with Fiberglass (flammability to UL 94V-0) Safety EMC http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -1- WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 VER : A_0 update : 94.03.21 AC-DC Power Module 3 0 Wa t t U l t r a m i niature Modular Switching Power Supplies ASC SERIES ELECTRICAL SPECIFICATIONS Model No. ( Dual* * riple Output ) T ASC-5D 30W 47-440 Hz 520 mA max. (115 VAC) / 320 mA max. (230 VAC) 10 A max. (115 VAC) /20 A max. (230 VAC) 0.75 mA max. 1.5 A slow blow type 5V 2% 3000 1% 3% 2% 3% 1% 470-23,000F depending on model <0.2% Vout +40mV max (Vp-p) <0.5% Vout +50mV max (Vp-p) 73% 15 ms min. 100 kHz Hiccup technique, auto-recovery Zener diode clamp Hiccup mode, indefinite (automatic recovery) 3000 V -25C...+70C (with derating) -40C...+85C 0.02%/C 95% RH >200,000 h @ 25C (MIL-HDBK-217F) 3.5 x 2.5 x 0.98 Inches 220 g Free air convection UL/cUL, CE, TUV, CB EN 55022 class B EN 55024 ASC 30 Watts series ASC-12D 30W ASC-15D 30W ASC-5S12S 30W ASC-5S12D 30W ASC-5S15D 30W Max Output Wattage (W) Voltage Frequency (Hz) Input 90-264 VAC or 120-370 VDC Current (Full load) Inrush Current (<2ms) Leakage Current External Fuse (recommend) Voltage (V.DC.) Voltage Accuracy Current (mA) max Line Regulation (LL-HL) (typ.) Load Regulation (5-00%) (typ.) Minimum Load Maximum Capacitive Load Ripple Noise Efficiency Hold-up Time Switching Frequency Over Power Protection 12V 1250 15V 1000 5/12 3000/1250 1% / 5% 2% / 6% 20% 5/12 3000/630 5/15 3000/500 Output 20% 20% 78% 76% 77% 77% 76% Protection Isolation Over Voltage Protection Short Circuit Protection Input-Output (V.AC) Operating Temperature Storage Temperature Environment Temperature Coefficient Humidity MTBF Dimension (L x W x H) Case Material Weight Cooling Method Agency Approvals EMI (Conducted & Radiated Emission) EMS (Noise Immunity) ( 89.0 x 63.5 x 25.0 mm ) Tolerance 0.5 mm Physical Plastic resin with Fiberglass (flammability to UL 94V-0) Safety EMC All specifications valid at nominal input voltage, full load and +25C after warm-up time unless otherwise stated. Note 1. 2. The triple output required a minimum 20% loading on the output to maintain specified regulation. damage these devices; however they may not meet all listed specification. Load regulation for triple output: Main output (V1): 20% to 100% with 20% to 100% balanced on auxiliaries. Auxiliary outputs (V2 and V3): 20% to 100% balanced on all outputs. Cross regulation for triple output: Main output 100% load, auxiliary 100%, other auxiliary 25% to 100%. Auxiliary outputs (V2 and V3): Main output 100% load, auxiliary 100%, other auxiliary 25% to 100% or main output 25%, auxiliary 25%, other auxiliary 25% to 100%. Operation under no-load condition will not 3. http://www.archcorp.com.tw TEL: +886-2-26989508 FAX: +886-2-26981319 -2- WWW.ASTRODYNE.COM 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 VER : A_0 update : 94.03.21 3 0 Wa t t U l t r a m i niature Modular Switching Power Supplies ASC SERIES ASC 30 Dual AC-DC Power Module Watts series MECHANICAL DIMENSION ( Top View ) PIN# SINGLE 5S/12S Triple AC IN (N) 1 AC IN (N) AC IN (N) AC IN (N) 2 AC IN (L) AC IN (L) AC IN (L) AC IN (L) 3 +DC OUT +DC OUT +12V +DC OUT 4 NO PIN NO PIN +5V +5V 5 -DC OUT COMMON +12 RTN COMMON 6 NO PIN NO PIN +5 RTN +5 RTN 7 NOCONNECT -DC OUT NO PIN -DC OUT BLOCK DIAGRAM DERATING WWW.ASTRODYNE.COM TEL: +886-2-26989508 FAX: +886-2-26981319 http://www.archcorp.com.tw 300 Myles Standish Blvd., Taunton, MA 02780 Ph: 1-800-823-8082 Fax: 508-823-8181 -3- |
Price & Availability of ASC |
|
|
All Rights Reserved © IC-ON-LINE 2003 - 2022 |
[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy] |
Mirror Sites : [www.datasheet.hk]
[www.maxim4u.com] [www.ic-on-line.cn]
[www.ic-on-line.com] [www.ic-on-line.net]
[www.alldatasheet.com.cn]
[www.gdcy.com]
[www.gdcy.net] |